In some cases it may be desirable to operate an auxiliary device in conjunction with the run signal for the wind machine. This modification of the WH110 will utilize pin 6 of the 12-pin deutsch connector to provide a ground for a relay when the run signal is active.
For this modification you will need the following:
- WH110 Harness
- Deutsch terminal removal tool
- Deutsch crimping tool
- 16ga male pin and white wire, or pre-crimped wire
- Electrical tape
Start by using the hook end of the terminal removal tool to hook into the center of the wedgelock.
Pull and remove the wedgelock.
Remove the sealing plug from position 6
Insert your crimped male-pin wire. Push through the seal until it clicks, then pull gently to ensure it's seated properly in the 12-pin connector.
The inside pins should look like this:
Replace the green wedgelock and snap it into place
Tape the white wire to the other wires to provide strain relief
The WH110 Aux Mod is Complete